Multi-parameter Mother / Fetal Patient Monitor YSD12MT

Item No.: YSD022
Multi-parameter Mother / Fetal  Patient Monitor
$0.00
INQUIRY
Description

Main Feature

12.1 inch color TFT screen

Built-in rechargeable battery with 2 hours working time

Networkable with central monitoring system

Parameters:

Mother: ECG,SPO2, NIBP, HR, TEMP, RESP, Pulse, Fetal heart rate,

Fetal movement, Contract pressure etc.

Fetal: Fetal heart rate, Fetal movement, Contract pressure etc.

Rotated Mouse Operation

Full-parameter 48 hours trend image, ECG cineloop

Fetal heart rate, Contraction pressure, Birth process cine-loop function

Compact design

Optional Recorder for printing

ECG

Connection mode: Five-cable electroniccardiograph input(R,L,F,N,C)

Connection method:I,II,III,AVR,AVL,AVF,V-

Number of display waveform:7

Gain options: 5.0mm/ mV, 10mm/ mV, 20mm/ mV,

Input impedance: ≥5MΩ

Total mold represses ratio: ≥ 100dB

Frequency response: Filter 0.540Hz(±3dB)

Protection: with standard voltage: I/P-O/P 4KVAC, 50Hz ±1Hz,Excursion get rid of

    Vibration, electric knife interference resistance, Av, the muscle

    electricity and drift interference resistance

The electrode sheds off the designation:Have

Scan speed:25mm/s, 50mm/s

S-T segment analysis:-2.0mV+2.0mV

NIBP

Measuring method: self-oscillation method

Operation mode: single time(Manual), Period (Auto)

Measuring parameters: Systolic pressure/Diastolic pressure

Measuring method: Adult, Child

Measuring range: Adult: 0300mmHg Children: 0145mmHg

Pressure unit: mmHg/Kpa

Alarm system: Audio-video alarm

SPO2

Display: Number of SPO2, waveform of capacity, Pulse

Measuring range: 0100%

Resolution: 1%

Accuracy: 70100% ( ±2%) , 4069% ( ±3%)

Type of the sensor: A wave-length gives out light the diode

Alarm system: Audio-video alarm

Pulse rate range: 20250bpm

Contractions Pressure

Category: Category B protection

Zero function: Amanual zero function

Pressure senstivity:0-100% for the whole design

Fetal Heart rate

Ultrasound probe: wide-angle lens polyerystalline

Category:B kind of protection direction detection

Operating frequency:25MHZ

Emissive power density:1.2mW/cm2

Sample: ±5ms

Fetal heart rate calculated precision: ±0.25 bpm

Fetal heart rate accuracy: ± bpm (100-180bpm)

TEMP

Type:Single road

Measuring range:0- 50

Unit:  °C / °F

Resolution: 0.1

Accuracy: ±0.1

Alarm range: 20-45 (top and bottom the limit trend into adjustable)

Alarm system: Audio-video alarm

Respiration

Display: Waves, Respiratory rate

Measuring range: 0100 pulses / min

Operation mode: Chest resistance

Measuring accuracy: ±2 pulses/ min

Scan speed: 25mm/s, 50mm/s

Alarm system: Audio-video alarm

Heart  rate

Measuring range:2 0254bpm

Accuracy: ±1bpm

Break time: A time per pulse

Alarm system: Audio-video alarm 

System

Display system: 12.1 ‘’ high-brightness color display

Resolution: 800*600

Trend diagram: 48 hours

Printer: Inside place a printer (option)

Network: Connect to the central machine

Power supply: AC220V±22V, 50Hz±1Hz

Dimmension: 320*160*270mm

G.W: 6KG

 

 

 