Contact Info
TEL: 028-84193018
FAX: 028-84193058
Add: 515,Building 1,NO39,Jiancai road,Chenghua district,Chengdu,Sichuan,China

Veterinary Multi-parameter Patient Monitor YSD12A-VET

Item No.: YSD023-V
Veterinary Multi-parameter Patient Monitor
$0.00
INQUIRY
Description

Main Feature

12.1 inch color TFT screen

Multi-display mode for selectable,such as big character interface

Waveform and data color can be set optionally

Storage of 480 hours trend data, and review of 34-second holographic waveform

Adopt digital SpO2 technology, strong in anti-interference and anti-weak filling capability

Review function for NIBP measurement, store up to 2400 groups of NIBP data

Be compatible with central monitoring system, connection mode: wireless and wired

Built-in removable and free-maintenance lithium battery for uninterrupted monitoring

Support the function of data storage for external U disk

Built-in thermal printer (option)

Preset alarm range can be automatically adjusted according different animal type

Animal type: cat(small animal), dog(medium animal), and other big animal

Suitable For

ECG

Lead mode: 3-lead /5-lead

Lead selection::I, II, III, aVR, aVL, aVF, V

Number of display waveform:7

Gain options: ×0.25 , ×0.5 , ×1, ×2

Measurement and alarm range for HR:

Range:15300 bpm

Accuracy:  ±1% or ± 1bpm, whichever is greater

Alarm accuracy: ±2bpm

Resolution: 12.5mm/s, 25mm/s, 50mm/s

ST segment monitoring: -0.8mv+0.8mv

Scan speed for waveform: 12.5mm/s, 25mm/s, 50mm/s

SPO2

Measurement and alram rang 0-100%

Resolution: 1%

Accuracy: 70100% ( ±2%),069% ,unspecified

Measurement and alarm range for PR: 0250bpm

Measurement accuracy for PR: ±2% or ± 2bpm, whichever is greater

NIBP

Method: Oscillometry

Working Mode: manual/Auto/Continuous

Measurement interval in AUTO mode: 1- 960 minutes

Measurement time in continuous mode: 5 minutes

Measurement range: 10-270mmHg

Accuracy: ±10%, ±8mmHg, whichever is greater

Over-pressure protection: dual-protection for software and hardware

RESP

Method: R-F(RA-LL) Impedance

Measurement and alarm range for RESP rate: 0120rpm

Accuracy: ±2rpm

Apnea alrm: 1040s

TEMP

Channel: dual-channel

Measurement and alarm range: 050

Resolution: 0.1

Accuracy: 0.1

Recorder (Optional)

Print mode: thermal array

Recording width: 48mm

Paper speed: 25mm/s, 50mm/s

Channel: dual-channel

Specification

Power Supply:AC100-240V,50/60 Hz

Power:≤150VA

Dimension:314mm*145mm*264mm

Weight:3.8KG

Accessories

Veterinary SpO2 probe 1m

SpO2 extension cable 2m

NIBP extension tube

NIBP joint

Nenatal repetitive cuff (6 11cm)

ECG lead

ECG electrode (child)

Veterinary ECG clip

Temperature probe (intracavitary type)

 

 

TOP